United States · design temperature
Heat pump sizing in Baton Rouge, LA
1 °C(33 °F) design temperature
Design temperature used for Baton Rouge, LA: 1 °C (33 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 1,325 heating degree-days (base 65 °F) per year
- 2,871 cooling degree-days (base 65 °F) per year
- 0 hours per year below 17 °F
Heating needs are low here, so the oversizing risk is mostly about cooling and part-load efficiency. Almost no hours per year fall below 17 °F, so low-temperature capacity rarely decides the choice. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 33 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 7,344 | 0.6 |
| 300 | 11,016 | 0.9 |
| 400 | 14,688 | 1.2 |
| 500 | 18,360 | 1.5 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.