Canada · design temperature
Heat pump sizing in Halifax, NS
−16 °C(3 °F) design temperature
Design temperature used for Halifax, NS: -16 °C (3 °F) — an estimate of the NBC 2.5 % January design temperature, from 10 years of reanalysis weather. Treat it as ±2 °C: your street can be colder or milder than the grid cell.
Recent winters (2015–2024) gave -13 °C (8 °F); the code value is an estimate of the NBC 1982–2006 figure (2.6 °C colder). Use your local code value if your contractor printed it.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 3 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 13,302 | 1.1 |
| 300 | 19,953 | 1.7 |
| 400 | 26,604 | 2.2 |
| 500 | 33,255 | 2.8 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Charlottetown, PE (-16 °C design)
- Moncton, NB (-20 °C design)
- Fredericton, NB (-21 °C design)
- St. John's, NL (-10 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.