Heat pump sizing in Lexington, KY

−9 °C(16 °F) design temperature

Try the free calculator

Design temperature used for Lexington, KY: -9 °C (16 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.

Climate at a glance

A moderate climate: most modern cold-climate and standard heat pumps cover the full load, and sizing to the design day is the main question. About 103 hours per year fall below 17 °F (−8 °C), where many heat pumps give up a large share of rated capacity: that is where a real capacity curve matters more than the nameplate tons. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.

What that means for load

Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 16 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:

UA (BTU/h·°F)Design load (BTU/h)≈ tons
20010,8000.9
30016,2001.4
40021,6001.8
50027,0002.3

Measure yours

Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.