Heat pump sizing in Philadelphia, PA
−8 °C(18 °F) design temperature
Design temperature used for Philadelphia, PA: -8 °C (18 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 18 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 10,296 | 0.9 |
| 300 | 15,444 | 1.3 |
| 400 | 20,592 | 1.7 |
| 500 | 25,740 | 2.1 |