Canada · design temperature
Heat pump sizing in Prince George, BC
−30 °C(-21 °F) design temperature
Design temperature used for Prince George, BC: -30 °C (-21 °F) — an estimate of the NBC 2.5 % January design temperature, from 10 years of reanalysis weather. Treat it as ±2 °C: your street can be colder or milder than the grid cell.
Recent winters (2015–2024) gave -27 °C (-17 °F); the code value is an estimate of the NBC 1982–2006 figure (2.6 °C colder). Use your local code value if your contractor printed it.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − -21 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 18,270 | 1.5 |
| 300 | 27,405 | 2.3 |
| 400 | 36,540 | 3.0 |
| 500 | 45,675 | 3.8 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Vancouver, BC (-4 °C design)
- Kelowna, BC (-18 °C design)
- Victoria, BC (-0 °C design)
- Red Deer, AB (-30 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.