United States · design temperature
Heat pump sizing in San Diego, CA
10 °C(50 °F) design temperature
Design temperature used for San Diego, CA: 10 °C (50 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 1,244 heating degree-days (base 65 °F) per year
- 611 cooling degree-days (base 65 °F) per year
- 0 hours per year below 17 °F
Heating needs are low here, so the oversizing risk is mostly about cooling and part-load efficiency. Almost no hours per year fall below 17 °F, so low-temperature capacity rarely decides the choice. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 50 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 3,996 | 0.3 |
| 300 | 5,994 | 0.5 |
| 400 | 7,992 | 0.7 |
| 500 | 9,990 | 0.8 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Irvine, CA (7 °C design)
- San Bernardino, CA (2 °C design)
- Los Angeles, CA (6 °C design)
- Las Vegas, NV (-0 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.