United States · design temperature
Heat pump sizing in Denver, CO
−14 °C(7 °F) design temperature
Design temperature used for Denver, CO: -14 °C (7 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 7 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 12,672 | 1.1 |
| 300 | 19,008 | 1.6 |
| 400 | 25,344 | 2.1 |
| 500 | 31,680 | 2.6 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.