United States · design temperature
Heat pump sizing in Duluth, MN
−23 °C(-9 °F) design temperature
Design temperature used for Duluth, MN: -23 °C (-9 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − -9 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 15,876 | 1.3 |
| 300 | 23,814 | 2.0 |
| 400 | 31,752 | 2.6 |
| 500 | 39,690 | 3.3 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Minneapolis, MN (-22 °C design)
- Fargo, ND (-25 °C design)
- Madison, WI (-19 °C design)
- Sioux Falls, SD (-20 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.