Heat pump sizing in Fresno, CA
3 °C(37 °F) design temperature
Design temperature used for Fresno, CA: 3 °C (37 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 1,961 heating degree-days (base 65 °F) per year
- 2,663 cooling degree-days (base 65 °F) per year
- 0 hours per year below 17 °F
A moderate climate: most modern cold-climate and standard heat pumps cover the full load, and sizing to the design day is the main question. Almost no hours per year fall below 17 °F, so low-temperature capacity rarely decides the choice. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 37 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 6,624 | 0.6 |
| 300 | 9,936 | 0.8 |
| 400 | 13,248 | 1.1 |
| 500 | 16,560 | 1.4 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.