United States · design temperature
Heat pump sizing in San Jose, CA
3 °C(38 °F) design temperature
Design temperature used for San Jose, CA: 3 °C (38 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 2,739 heating degree-days (base 65 °F) per year
- 320 cooling degree-days (base 65 °F) per year
- 0 hours per year below 17 °F
A moderate climate: most modern cold-climate and standard heat pumps cover the full load, and sizing to the design day is the main question. Almost no hours per year fall below 17 °F, so low-temperature capacity rarely decides the choice. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 38 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 6,372 | 0.5 |
| 300 | 9,558 | 0.8 |
| 400 | 12,744 | 1.1 |
| 500 | 15,930 | 1.3 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.