Canada · design temperature
Heat pump sizing in Ottawa, ON
−27 °C(-17 °F) design temperature
Design temperature used for Ottawa, ON: -27 °C (-17 °F) — an estimate of the NBC 2.5 % January design temperature, from 10 years of reanalysis weather. Treat it as ±2 °C: your street can be colder or milder than the grid cell.
Recent winters (2015–2024) gave -24 °C (-12 °F); the code value is an estimate of the NBC 1982–2006 figure (2.6 °C colder). Use your local code value if your contractor printed it.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − -17 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 17,370 | 1.4 |
| 300 | 26,055 | 2.2 |
| 400 | 34,740 | 2.9 |
| 500 | 43,425 | 3.6 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Kingston, ON (-19 °C design)
- Toronto, ON (-15 °C design)
- Hamilton, ON (-17 °C design)
- Sudbury, ON (-28 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.