United States · design temperature
Heat pump sizing in Evansville, IN
−9 °C(15 °F) design temperature
Design temperature used for Evansville, IN: -9 °C (15 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 3,885 heating degree-days (base 65 °F) per year
- 1,731 cooling degree-days (base 65 °F) per year
- 115 hours per year below 17 °F
A moderate climate: most modern cold-climate and standard heat pumps cover the full load, and sizing to the design day is the main question. About 115 hours per year fall below 17 °F (−8 °C), where many heat pumps give up a large share of rated capacity: that is where a real capacity curve matters more than the nameplate tons. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 15 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 10,980 | 0.9 |
| 300 | 16,470 | 1.4 |
| 400 | 21,960 | 1.8 |
| 500 | 27,450 | 2.3 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Louisville, KY (-9 °C design)
- Nashville, TN (-6 °C design)
- Indianapolis, IN (-13 °C design)
- St. Louis, MO (-11 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.