United States · design temperature
Heat pump sizing in St. Louis, MO
−11 °C(12 °F) design temperature
Design temperature used for St. Louis, MO: -11 °C (12 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 12 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 11,556 | 1.0 |
| 300 | 17,334 | 1.4 |
| 400 | 23,112 | 1.9 |
| 500 | 28,890 | 2.4 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Springfield, IL (-13 °C design)
- Evansville, IN (-9 °C design)
- Indianapolis, IN (-13 °C design)
- Kansas City, MO (-13 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.