United States · design temperature
Heat pump sizing in Phoenix, AZ
4 °C(39 °F) design temperature
Design temperature used for Phoenix, AZ: 4 °C (39 °F) — the 99 % annual heating design temperature, from 10 years of reanalysis weather. Treat it as ±1 °C: your street can be colder or milder than the grid cell.
Climate at a glance
- 1,092 heating degree-days (base 65 °F) per year
- 4,685 cooling degree-days (base 65 °F) per year
- 0 hours per year below 17 °F
Heating needs are low here, so the oversizing risk is mostly about cooling and part-load efficiency. Almost no hours per year fall below 17 °F, so low-temperature capacity rarely decides the choice. Averages of 2015–2024 reanalysis weather for the grid cell around this city, not your street.
What that means for load
Design heat load = your home's heat-loss coefficient (UA) × (70 °F − 39 °F). Illustrative only — your own UA is what matters, and a contractor's quote is often sized from a rule of thumb instead:
| UA (BTU/h·°F) | Design load (BTU/h) | ≈ tons |
|---|---|---|
| 200 | 6,192 | 0.5 |
| 300 | 9,288 | 0.8 |
| 400 | 12,384 | 1.0 |
| 500 | 15,480 | 1.3 |
Measure yours
Temsor RightSize reads 12–24 months of your utility bills, fits your real UA with an uncertainty range, and checks the heat pump you were quoted against real cold-climate capacity data. Try the free calculator.
Nearby cities
- Tucson, AZ (2 °C design)
- Las Vegas, NV (-0 °C design)
- San Bernardino, CA (2 °C design)
- San Diego, CA (10 °C design)
Engineering estimate, not a stamped Manual J / permit document. Method validated on simulated homes. See the disclaimer.